Skip to content

Estimate unknown spectra

Use the same noisy ternary image, this time supplying only the image and an expected component count of three. First select three starting spectra directly from the image and use them to estimate the component maps. Then refine the spectra with multivariate curve resolution by alternating least squares (MCR-ALS).

Run the blocks below in order using the environment from the quickstart.

Simulate the input image

Build a triangle with pure EBFP2 at the top, EGFP at the bottom left, and mCherry at the bottom right. Inside the triangle, each pixel has 500 expected counts across all detector channels. Add shot noise to create the image the unmixing workflow will receive. The reference spectra and true component maps are kept for the final comparison.

import numpy as np

from lumic.simulation import (
    SpectralDetector,
    add_confocal_noise,
    load_offline_emission_spectrum,
    simulate_linear_mixture,
)

names = ("EBFP2", "EGFP", "mCherry")
detector = SpectralDetector.from_profile("980_32ch")
spectra = np.array([
    detector.sample(*load_offline_emission_spectrum(name))
    for name in names
])
spectra /= spectra.sum(axis=1, keepdims=True)

size = 81
total_counts = 500.0
y, x = np.indices((size, size), dtype=float)

# Use vertices (x, y) of (40, 4), (4, 68), and (76, 68).
blue = (68 - y) / 64
red = (x - 4 - 36 * blue) / 72
green = 1 - blue - red
fractions = np.stack((blue, green, red), axis=-1)
inside = np.all(fractions >= -1e-12, axis=-1)
true_counts = total_counts * np.where(
    inside[..., None], np.clip(fractions, 0, 1), 0,
)

simulation = simulate_linear_mixture(
    true_counts, spectra, detector.channel_centers, fluorophore_names=names,
)
noisy = add_confocal_noise(simulation.image, rng=np.random.default_rng(2026))

Estimate spectra directly from the image

Unfold the image into one row per pixel. For this simulation, the background outside the triangle is exactly zero, so we exclude zero-signal pixels from spectral estimation. The convex hull selects candidates at the extremes of a low-dimensional spectral projection. unique_profiles selects three spectra from that candidate set. The selection uses the measured spectra without needing the triangle coordinates or the simulated references.

from lumic import SpectralImage, essential_spectral_pixles, unique_profiles

n_components = 3
image = SpectralImage(data=noisy, axes="YXC", wavelengths_nm=detector.channel_centers)
unfolded = image.unfold()
pixels = unfolded.data
signal_pixels = pixels[pixels.sum(axis=1) > 0]

hull_spectra, _ = essential_spectral_pixles(signal_pixels, npc=n_components)
initial_spectra, _ = unique_profiles(hull_spectra.T, nr=n_components, f=1.0)
initial_spectra = initial_spectra / initial_spectra.sum(axis=1, keepdims=True)
print(f"Selected {n_components} starting spectra from {len(hull_spectra)} candidates")

The three starting spectra are individual noisy pixel spectra. Normalize each to sum to one across the detector channels so its fitted contribution is in counts. Use nonnegative least squares to estimate those contributions for every pixel with the spectra held fixed.

from lumic import positive_least_squares

initial_counts = positive_least_squares(pixels, initial_spectra, solver="auto")
initial_maps = unfolded.fold_abundances(initial_counts)

Refine the spectra with MCR-ALS

MCR-ALS alternates between fitting component contributions and updating the spectra. The hull supplies the starting spectra. For this small example, we use all signal pixels during refinement so mixtures inside the triangle also contribute. We allow up to 200 updates and set a stopping tolerance of 0.01% relative improvement per update.

from lumic import mcr_als

_, refined_spectra, history, diagnostics = mcr_als(
    signal_pixels, initial_spectra, nIter=200, normL="L1",
    tol_percent=0.01, return_diagnostics=True,
)
refined_counts = positive_least_squares(pixels, refined_spectra, solver="auto")
refined_maps = unfolded.fold_abundances(refined_counts)
print(f"{diagnostics.iterations_completed} updates ({diagnostics.stop_reason})")
print(f"Relative lack of fit: {history[0]:.1%} → {diagnostics.best_relative_l2:.1%}")

With the tutorial's noise seed, the solver converges in three updates and the relative lack of fit drops from 20.8% to 17.9%. This measure is the norm of the reconstruction residual divided by the norm of the measured signal.

Compare with the known simulation

The fit can return components in any order. For this comparison only, use match_components to pair each recovered spectral shape with a simulated reference. Apply the same ordering to the maps.

from lumic.evaluation import match_components

initial_order, _ = match_components(spectra, initial_spectra)
refined_order, _ = match_components(spectra, refined_spectra)

for stage, basis, maps, order in (
    ("Initial", initial_spectra, initial_maps, initial_order),
    ("Refined", refined_spectra, refined_maps, refined_order),
):
    channel_error = 100 * np.abs(basis[order] - spectra)
    count_error = np.abs(maps.data[..., order] - true_counts)
    print(stage)
    for index, name in enumerate(names):
        print(
            f"  {name}: mean channel error {channel_error[index].mean():.3f} pp, "
            f"largest channel error {channel_error[index].max():.3f} pp, "
            f"mean map error {count_error[inside, index].mean():.1f} counts"
        )

For each of the three fluorophores, the refined spectrum is closer to the simulated reference than the selected starting spectrum. A fourth panel shows lack of fit dropping over three MCR-ALS updates.

Each spectrum is expressed as a percentage of its total signal. Channel errors are differences on that scale in percentage points (pp). The largest channel error falls from about 2 percentage points for each component to below 0.3 after refinement.

Three columns show EBFP2, EGFP, and mCherry. The rows show the true maps, maps fitted with the initial spectra, and maps fitted with the refined spectra, all on the same count scale.

The component maps already look similar after the initial fit. Refinement improves their mean absolute error by less than one count per component, even though the spectra improve visibly.

See Recover a spectrum without pure pixels for a mixture where EGFP always appears alongside another fluorophore.

Use the fitted image to inspect reconstruction errors or measure simulation recovery.