Simulation API
Use the simulation API to create spectral images with known component maps and spectra. You can use bundled emission curves offline and choose whether to work with a clean image or simulate a noisy acquisition.
| If you want to… | Use |
|---|---|
| Load a bundled FPbase emission curve | load_offline_emission_spectrum() |
| Interpolate a curve at specific wavelengths | resample_spectrum() |
| Integrate a curve over detector bands | SpectralDetector.sample() |
| Mix spectra that are already on a shared detector grid | simulate_linear_mixture() |
| Add count noise to an existing clean detector image | add_confocal_noise() |
| Sample emission curves, mix components, and add noise in one call | simulate_noisy_image() |
Emission curves and detector sampling
load_offline_emission_spectrum() returns a pair of one-dimensional arrays
containing wavelengths in nanometres and relative emission intensities.
resample_spectrum() interpolates intensity at each requested wavelength.
In contrast, SpectralDetector.sample() integrates intensity across the
width of each band, producing one value per detector channel in input
intensity times nanometres. Neither operation normalizes the result.
The built-in 980_32ch profile is an idealized model of one LSM 980 setting
with band edges inferred from channel labels. For a custom detector with
known contiguous bands, supply their edges to SpectralDetector().
from_centers() can infer edges when only channel centers are known.
See Load and prepare spectra for saving sampled curves as
reusable references.
SpectralDetector
SpectralDetector(bin_edges, *, channel_centers=None, name=None, nominal_resolution_nm=None)
Integrate spectral intensity within contiguous detector channels.
bin_edges has one more value than the number of channels. The
sample method treats the supplied intensity as a piecewise-linear
spectral density and returns its integral in each channel. The spectrum
is taken to be zero outside its measured wavelength range.
bin_edges
property
bin_edges
Wavelength boundaries of the channels, in nm.
channel_centers
property
channel_centers
Nominal wavelength labels of the channels, in nm.
n_channels
property
n_channels
from_centers
classmethod
from_centers(channel_centers, *, name=None, nominal_resolution_nm=None)
Infer contiguous bin edges halfway between adjacent center labels.
The two outer edges are extrapolated by half the nearest center spacing. At least two centers are needed to infer a width.
from_profile
classmethod
from_profile(name)
Build a named ideal detector profile.
sample
sample(wavelengths, intensities)
Return the integrated signal in each spectral channel.
Source samples are connected by straight lines. Input intensity is not normalized; output values have intensity-times-nm units. This is deterministic binning and does not add measurement noise.
load_offline_emission_spectrum(name, *, directory=None)
Load a saved FPbase emission curve by fluorophore name.
By default this reads the FPbase snapshot bundled with Lumic.
Pass directory to use another collection of the same CSV files. This
function has the same name -> (wavelengths, intensities) interface as
lumic.fpbase.fetch_emission_spectrum, so scene geometry does not depend
on where its spectra come from.
resample_spectrum(wavelengths, intensities, target_wavelengths)
Interpolate a spectrum onto a wavelength grid.
Values outside the measured wavelength range are set to zero. Input intensities are preserved as supplied; this function does not normalize.
Mix components and simulate noise
Simulation arrays use channels last. Component maps have shape
(Y, X, K), the component matrix has shape (K, C), and the output
detector image has shape (Y, X, C). The names and component maps follow
the row order of the component matrix. When wrapping the output in a
SpectralImage, pass axes="YXC".
simulate_linear_mixture() uses the component spectra at their supplied
scale. If each row sums to one, the component maps can represent expected
counts per component. simulate_noisy_image() integrates the input curves
and normalizes the sampled rows for you. It keeps the clean expected counts,
the noisy image, and the basis used to form the clean image.
import numpy as np
from lumic.simulation import (
SpectralDetector,
load_offline_emission_spectrum,
simulate_noisy_image,
)
names = ("EGFP", "mCherry")
detector = SpectralDetector.from_profile("980_32ch")
curves = [load_offline_emission_spectrum(name) for name in names]
component_counts = np.array([[[100.0, 50.0], [50.0, 100.0]]])
result = simulate_noisy_image(
component_counts,
curves,
detector,
fluorophore_names=names,
rng=np.random.default_rng(2026),
)
clean = result.expected_counts # (1, 2, 32)
noisy = result.noisy_image # (1, 2, 32)
basis = result.ideal.spectra # (2, 32), unit-sum detector spectra
Noise is drawn in count units. The Poisson draw models shot noise.
Set gaussian_sigma above zero to add independent Gaussian noise with
that standard deviation. Observations below zero after adding noise are
clipped to zero. Pass a seeded generator to reproduce a draw.
simulate_linear_mixture(abundances, spectra, wavelengths, fluorophore_names=None)
Form a noiseless (y, x, wavelength) image as abundances @ spectra.
add_confocal_noise(expected_counts, *, gaussian_sigma=0.0, rng=None)
Draw one noisy measurement for every pixel and spectral channel.
expected_counts is the clean detector image in expected count units.
Draw Poisson counts, add independent zero-mean Gaussian noise in the same
units, then clip negative observed values to zero. The input is unchanged.
Pass a seeded numpy.random.Generator for reproducible results.
simulate_noisy_image(component_counts, component_spectra, detector, *, fluorophore_names=None, gaussian_sigma=0.0, rng=None)
Simulate recorded counts from per-pixel fluorophore contributions.
component_counts[y, x, k] is the expected number of recorded counts
supplied by component k at that pixel, across all detector channels.
component_spectra holds one (wavelengths, intensities) pair per
component. Each spectrum is integrated by detector and normalized to
unit sum, so the clean image sums to component_counts.sum(axis=-1).
The result retains that clean image and an independently noisy image. Spectra with no signal in the detector's wavelength range are rejected.
Result containers
SyntheticDataset holds the clean image and the ground truth used to form
it. In NoisySimulationResult, ideal is that clean dataset.
sampled_spectra holds the integrated rows before normalization, and
source_spectra holds the original wavelength and intensity pairs.
SyntheticDataset
dataclass
An ideal spectral image and the ground truth used to construct it.
Image axes are (y, x, wavelength) and abundance axes are
(y, x, fluorophore).
image
instance-attribute
abundances
instance-attribute
spectra
instance-attribute
wavelengths
instance-attribute
fluorophore_names
instance-attribute
NoisySimulationResult
dataclass
Clean count image, noisy measurement, and detector ground truth.
ideal.abundances contains expected per-component recorded counts and
ideal.spectra contains the normalized detector spectra. The sampled
spectra retain their original integrated intensity scale, and
source_spectra retains the curves before detector sampling.
ideal
instance-attribute
expected_counts
property
Clean expected detector counts, with axes (y, x, channel).
noisy_image
instance-attribute
detector
instance-attribute
source_spectra
instance-attribute
sampled_spectra
instance-attribute
gaussian_sigma
instance-attribute
For a complete workflow, see Simulate a spectral image and Evaluate simulation recovery.