Skip to content

Load spectral images

Lumic uses the same reader interface for ZEISS CZI and OME-TIFF. Start with open_image() to inspect a file before loading its pixels, or use load_image() when you already know which plane you want. A plain TIFF without OME-XML is outside the OME-TIFF reader's scope.

Download the public COS-7 example

Use lumic.data.download_cos7_data() to fetch the COS-7 acquisitions. See the backend quickstart for installation and the COS-7 notebook for a full unmixing run.

By default the function downloads only the high-SNR mixed CZI (about 145 MB). Use the returned path to load the image from a script or notebook.

from lumic.data import download_cos7_data
from lumic.io import load_image

path, = download_cos7_data(progress=True)
image = load_image(path)

Set snr="medium" or snr="low" for another condition, or snr="all" for all three mixed acquisitions. Set include_references=True to add the three single-stain files for each selected condition. All twelve files together take about 1.74 GB.

Downloads go to ~/.lumic/data/bioimage-archive/S-BIAD4448/ by default. Pass data_dir= to choose a different folder. The downloader keeps conditions in separate subfolders and reuses files that match the archive's expected byte size. Set progress=True for percentage updates while each file downloads. The command-line example shows progress by default and accepts the same SNR and reference choices.

python Python/examples/download_cos7_data.py --snr all --include-references

The images are available under CC0. BioImage Archive accession S-BIAD4448

Inspect and load a plane

Install Lumic using the backend quickstart. To try both formats, run this example from the repository root. It uses a small CZI Z stack and its paired OME-TIFF export under Python/data/io-data/. To use your own files, replace the paths with a CZI or OME-TIFF that you have locally.

from pathlib import Path

from lumic.io import open_image

fixtures = Path("Python/data/io-data")
paths = [
    fixtures / "980/ex405-range411_694-res8p8nm_zstack3.czi",
    fixtures / "980-ome-tiff/ex405-range411_694-res8p8nm_zstack3.ome.tiff",
]

for path in paths:
    with open_image(path) as reader:
        print(reader.summary())
        image = reader.read(t=0, z=1)

    print("Loaded plane:", image.axes, image.data.shape)
    print("Pixel sizes (µm):", image.pixel_sizes_um)
    print("Wavelength coordinates (nm):", image.wavelengths_nm)
    print("Detection bands available:", image.detection_bands_nm is not None)

The summary describes the available stack before selection. Both fixtures have 32 detector channels and three Z planes. With zero-based indexing, z=1 loads the second plane. Both selected arrays have axes CYX and shape (32, 32, 32). The loaded image remains usable after the reader closes.

For a direct load, use the same selection arguments:

from lumic.io import load_image

# Load all Z planes at the first time point from either file above.
stack = load_image(paths[0], t=0, z=None)
print(stack.axes, stack.data.shape)  # CZYX (32, 3, 32, 32) for this fixture.

The default is t=0, z=0. Use None to keep all positions along that dimension. An explicit series argument selects an OME-TIFF image series when the file contains more than one. Check image.axes before indexing, since the axis order can differ across files.

What metadata does Lumic return?

Attribute What it tells you
image.axes The order of dimensions in image.data. C is detector channel, Y and X are lateral axes, Z is depth, and T is time.
image.pixel_sizes_um Available physical pixel sizes in micrometres, keyed by spatial axis. Missing calibration leaves the relevant key absent.
image.wavelengths_nm An optional wavelength coordinate for each detector channel.
image.detection_bands_nm Optional lower and upper detection bounds in nanometres for each channel.
image.provenance Source details such as file format, original axes and plane selection. For OME-TIFF it also records the series, stored channel names, and the source of the wavelength coordinates when available.

CZI. Lumic reads recorded detection windows when available. For ordered, non-overlapping windows with positive width, it uses the midpoint of each window as the wavelength coordinate. Overlapping acquisition windows can retain their bounds with wavelengths_nm=None.

OME-TIFF. Lumic reads spatial calibration from OME-XML and can get wavelength coordinates from emission wavelength fields or channel names that are all numeric labels such as 415 nm. The paired OME-TIFF in this example retains rounded wavelength labels but lacks detector window bounds. Lumic's own OME-TIFF exports can preserve available detector bounds and coordinates in a versioned annotation.

Treat missing spectral metadata as unknown. Detector channels are measurements that can contain contributions from several fluorophores.