Spectra API
Use Spectrum for a single spectral signature and SpectrumCollection
for several signatures sampled on the same grid. A collection stores one
row per component and one column per wavelength sample or detector channel.
It keeps the shared axis and optional detector bands alongside the matrix,
with a name and source information for each row.
Choose a container
| Task | Use |
|---|---|
| Keep or exchange one signature | Spectrum with a one-dimensional values array |
| Group aligned signatures with their names and provenance | SpectrumCollection.from_spectra() |
| Attach a shared grid to an existing component matrix | SpectrumCollection(values, wavelengths_nm=..., detection_bands_nm=...) |
| Recover one signature from a collection | collection.spectrum(index) |
When grouping spectra, sample counts and wavelength coordinates must match
exactly in the same order, or all spectra must omit wavelength coordinates.
The collection does not resample, sort, or normalize its inputs. If wavelengths
are unavailable, leave wavelengths_nm unset and verify channel order from the
acquisition. Matching wavelength centers alone does not establish that two
detector grids are compatible. Check the detector bands when available.
Save and reuse references
Both containers have save_json() and load_json() methods. Use the class
that matches the file format: lumic-spectrum for a single signature,
lumic-spectrum-collection for a shared-axis matrix. The latter stores the
wavelength axis and detector bands once. Provenance must be JSON compatible
when saved.
from lumic import Spectrum, SpectrumCollection
wavelengths = [500, 510, 520]
reference_a = Spectrum([0.2, 0.5, 0.3], wavelengths, name="A")
reference_b = Spectrum([0.5, 0.4, 0.1], wavelengths, name="B")
references = SpectrumCollection.from_spectra([reference_a, reference_b])
references.save_json("references.json")
restored = SpectrumCollection.load_json("references.json")
first_reference = restored.spectrum(0)
component_matrix = restored.values # (2, 3), components × samples
Pass component_matrix to the solver when its columns match the detector
channels of the observations. See Load and prepare spectra
for a detector sampling example and
Unmixing and spectral selection for fitting.
Single spectrum
Spectrum
dataclass
Spectrum(values, wavelengths_nm=None, name=None, provenance=dict())
Keep a spectrum's values, wavelength labels and source information together.
values is a nonempty, finite, one-dimensional array of real intensities.
Optional wavelengths_nm contains one finite, positive coordinate per
value, in the same order. Use name for the label and provenance for
descriptive information about acquisition or processing.
Arrays are copied at construction. Values retain their dtype, order and scale. Wavelength labels alone do not establish compatibility with an image's detector channels. Pass ordinary NumPy arrays to the solvers.
values
instance-attribute
values
wavelengths_nm
class-attribute
instance-attribute
wavelengths_nm = None
name
class-attribute
instance-attribute
name = None
provenance
class-attribute
instance-attribute
provenance = field(default_factory=dict)
save_json
save_json(path)
Save a version 1 Lumic spectrum to a UTF-8 JSON file.
Preserve sample order, scale, and numeric dtypes up to 64 bits. Provenance must contain JSON objects with string keys, lists, strings, booleans, finite Python numbers or None; unsupported objects raise TypeError. Serialization is validated before opening the destination. An existing file is overwritten. Parent directories must exist.
Example: spectrum.save_json("reference.spectrum.json").
load_json
classmethod
load_json(path)
Read a JSON spectrum written by :meth:save_json.
Validate the format version, numeric dtypes, samples and metadata. Missing wavelength coordinates remain None. No normalization, interpolation, or sorting is performed. Invalid files raise ValueError (including JSONDecodeError); file access errors propagate normally.
Example: spectrum = Spectrum.load_json("reference.spectrum.json").
Spectrum collection
SpectrumCollection
dataclass
SpectrumCollection(values, wavelengths_nm=None, *, detection_bands_nm=None, names=None, row_provenance=None, provenance=None)
Ordered component spectra on a common sample axis.
Rows in values represent components and columns represent samples.
The matrix must be nonempty, real and finite. Optional wavelengths_nm
has one positive coordinate per sample. Optional detection_bands_nm
has one pair of positive lower and upper bounds per sample. Each axis
follows the matrix's column order, including any repeated coordinates.
Arrays are copied and exposed as read-only views.
names and row_provenance contain one name (or None) and one mapping
per row, respectively. provenance describes the whole collection.
Detector bands in row provenance must agree exactly in sample order and
must occur in every row or none. When present, they provide the shared
detector bands and must match any explicitly supplied bands. The reserved
detection_bands_nm key is stored as the shared axis and exported in the
provenance of each extracted Spectrum.
values
property
values
The component-by-sample matrix.
wavelengths_nm
property
wavelengths_nm
The shared wavelength coordinate array, if available.
detection_bands_nm
property
detection_bands_nm
The shared detector bounds, if available.
names
instance-attribute
names
row_provenance
property
row_provenance
Independent copies of the descriptive metadata for each row.
provenance
instance-attribute
provenance
from_spectra
classmethod
from_spectra(spectra, *, detection_bands_nm=None, provenance=None)
Stack Spectrum objects in iteration order, using a common dtype.
Sample counts and wavelength labels must agree exactly in order. All rows may omit wavelengths. Stacking raises ValueError if dtype promotion would change a sample. No samples are sorted, normalized or interpolated.
spectrum
spectrum(index)
Return an independent Spectrum at an integer row index.
Shared detector bands are carried in the Spectrum's provenance.
save_json
save_json(path)
Save a version 1 Lumic spectrum collection as UTF-8 JSON.
Preserve row and sample order, scale, and numeric dtypes up to 64 bits. Store the optional sample axes once for the collection. Collection and row provenance must contain only JSON-compatible values. Validate serialization before overwriting an existing file.
load_json
classmethod
load_json(path)
Read a version 1 file written by :meth:save_json.
Preserve component order, sample order, and recorded numeric dtypes. Invalid files raise ValueError. File access errors propagate normally.